Skip to main content

Division 27 & Facility Infrastructure

Data Center Construction & Fit-Out

Code-compliant plenum and MPO optical pathways, 19-inch redundant rack frames, air-gapped NOC/SOC KVM extenders, and gray-space electrical isolation engineered for modern server halls and colocation buildouts.

Optical fiber strands routed in front of illuminated data center server racks
  • Plenum & LSZH Rated
  • MPO / OM3 / OS2 Ready
  • 19” 1RU Redundant Power
  • Zero-Latency Optical KVM
  • 5 kV Galvanic Isolation
  • Zero IP Attack Surface
Technical Overview

Bridging White Space, Gray Space & NOC Suites

While spine-and-leaf switches handle east-west packet traffic, data center construction teams still have to move uncompressed operator video, out-of-band KVM, USB peripherals, and BMS telemetry across fire-rated plenums, high-EMI power rooms, and badge-restricted cages.

Our catalog equips Division 27 integrators and facility engineers with Plenum, LSZH, and UL-certified optical assemblies, native MPO/LC/SC patch-panel modules, and bus-powered cables that save valuable rack PDU outlets.

In gray-space mechanical and electrical rooms, passive 5 kV galvanic network isolators and 24V DC / 85°C industrial hubs protect monitoring networks against ground potential differences, switching transients, and ESD.

MDF / IDF Rack Architecture

Eliminate Loose Power Bricks in Equipment Cabinets

Individual DC wall adapters clutter zero-U vertical raceways and create single-PSU failure points. The Opticis BR-600 19” 1RU frame consolidates up to eight Snap-Lock optical transmitters or receivers with dual load-sharing DC inputs via locking barrel and Phoenix terminal connectors.

When populated with diagnosis-enabled DPX-1F12-TR, HDX-1F20-TR, or DHX-1F4K-TR modules, operators gain RJ45 LAN status monitoring, event logging, remote port power cycling, and simultaneous firmware upgrades across 300-meter single-LC trunks.

Opticis BR-600 19-inch 1RU rack chassis populated with LC fiber optical extender modules and RJ45 management port
Verified Catalog by Build Phase

Data Center Hardware by Build Phase

Organized across 4 facility subsystems (35 verified SKUs) for low-voltage rough-in, cabinet integration, NOC buildouts, and BMS isolation.

35 SKUs 4 Systems
Phase 01 Pathways & Patching
10 SKUs

Plenum, LSZH & MPO Structured Cabling

Fire-code-compliant active optical runs, conduit-pullable detachable heads, and OM3 MPO/LC patch assemblies engineered for raised-floor air plenums, overhead ladder racks, and pre-terminated trunk panels.

  • NEC Art. 645 / CMP Plenum
  • LSZH Low-Smoke Jackets
  • 12-Core OM3 MPO & LC
  • Detachable Conduit Heads
Opticis DPOC-14N-P DisplayPort 1.4 Active Optical Cable, 8K60 DSC, Plenum
View Opticis DPOC-14N-P DisplayPort 1.4 Active Optical Cable, 8K60 DSC, Plenum
opticisDPOC14NP-10M

Opticis DPOC-14N-P DisplayPort 1.4 Active Optical Cable, 8K60 DSC, Plenum

Opticis DPOC-14N-P DisplayPort 1.4 active optical cable supporting up to 8K@60Hz DSC over distances up to 100m, with no external power required.

$329.00USD

Opticis DPFC-200D Detachable DisplayPort 1.2 AOC | 4K60, 100m Plenum/LSZH
View Opticis DPFC-200D Detachable DisplayPort 1.2 AOC | 4K60, 100m Plenum/LSZH
opticisDPFC-200D-10

Opticis DPFC-200D Detachable DisplayPort 1.2 AOC | 4K60, 100m Plenum/LSZH

Detachable DisplayPort 1.2 active optical cable extending uncompressed 4K@60Hz video up to 100 meters over plenum or LSZH hybrid fiber.

$449.00USD

Opticis DHFC-200D Detachable DP 1.2 to HDMI 2.0 AOC | 4K60, 100m Plenum/LSZH
View Opticis DHFC-200D Detachable DP 1.2 to HDMI 2.0 AOC | 4K60, 100m Plenum/LSZH
opticisDHFC-200D-10

Opticis DHFC-200D Detachable DP 1.2 to HDMI 2.0 AOC | 4K60, 100m Plenum/LSZH

Detachable DisplayPort 1.2 to HDMI 2.0 active optical cable with high-retention HDMI, extending uncompressed 4K@60Hz up to 100m over hybrid fiber.

$449.00USD

Opticis HDMI 2.0 Detachable Active Optical Cable, 4K60, up to 100m (LHM2-P Series)
View Opticis HDMI 2.0 Detachable Active Optical Cable, 4K60, up to 100m (LHM2-P Series)
opticisLHM2-PP-10

Opticis HDMI 2.0 Detachable Active Optical Cable, 4K60, up to 100m (LHM2-P Series)

Detachable HDMI 2.0 active optical cable supporting 4K DCI 60Hz over distances up to 100m with HDR and HDCP 2.2 support.

$199.00USD

Opticis LHM2-N HDMI 2.0 Active Optical Cable | 100m 4K HDR Fiber HDMI Cable
View Opticis LHM2-N HDMI 2.0 Active Optical Cable | 100m 4K HDR Fiber HDMI Cable
opticisLHM2-NP-10

Opticis LHM2-N HDMI 2.0 Active Optical Cable | 100m 4K HDR Fiber HDMI Cable

HDMI 2.0 active optical cable supporting uncompressed 4K (4096×2160) @ 60Hz with HDR over hybrid fiber up to 100 m. No external power required.

$199.00USD

Opticis USB-FC30AA USB 3.0 Active Optical Cable, Plenum Rated
View Opticis USB-FC30AA USB 3.0 Active Optical Cable, Plenum Rated
opticisUSBFC30AA-10M

Opticis USB-FC30AA USB 3.0 Active Optical Cable, Plenum Rated

Opticis USB 3.0 active optical cable with USB-A to USB-A connectors. Supports 5Gbps data over long distances using plenum-rated hybrid fiber cable.

$369.00USD

Opticis USB 3.2 Gen 2x1 Active Optical USB-C Cable, UL Certified
View Opticis USB 3.2 Gen 2x1 Active Optical USB-C Cable, UL Certified
opticisUSC-CC32-10UL

Opticis USB 3.2 Gen 2x1 Active Optical USB-C Cable, UL Certified

UL-certified Opticis USB-C active optical cable supporting USB 3.2 Gen 2x1 (10Gbps), DisplayPort Alt Mode 4K@60Hz, and up to 100W power delivery at 10m.

$475.00USD

SC to SC OM3 Simplex Patch Cord | 50/125 Multimode LSZH
View SC to SC OM3 Simplex Patch Cord | 50/125 Multimode LSZH
opticisSSMS050

SC to SC OM3 Simplex Patch Cord | 50/125 Multimode LSZH

SC-SC OM3 50/125 multimode simplex patch cord with an LSZH jacket, ≤0.3 dB insertion loss, and specified order length with ±3% tolerance.

Standard ConfigurationDirect SKU

$100.00USD

Phase 02 MDF / IDF Consolidation
8 SKUs

19” 1RU Rack Power & Managed Optical Links

High-density 1RU Snap-Lock chassis with dual load-sharing DC inputs and RJ45 LAN diagnostics, paired with single-fiber LC optical extenders to eliminate loose power bricks in equipment cabinets.

  • 19-Inch 1RU Snap-Lock
  • Dual Redundant DC + Phoenix
  • LAN GUI Diagnostics
  • 300m over 1 LC OM3/OM4
Phase 03 White-Space Separation
9 SKUs

White-Space KVM Separation & NOC Video Walls

Air-gapped optical KVM switches, multi-port OS2 single-mode USB systems, PoE IP video wall controllers, and rough-in wall plates separating restricted server cages from NOC, SOC, and briefing suites up to 1 km away.

  • Up to 1 km OS2 / 300m MM
  • Non-Routable Physical Layer
  • 802.3af PoE Video Wall
  • 1-Gang Fiber Rough-In
Phase 04 BMS Isolation & Bulkheads
8 SKUs

Gray-Space BMS Isolation & Server Cabinet Hardware

Passive 5 kV galvanic Ethernet isolators for UPS, switchgear, and chiller telemetry, 24V DC high-temp USB hubs for BMS control panels, Neutrik rack-panel repeaters, and server/crash-cart interfaces.

  • 5 kV AC Galvanic Isolation
  • 24V DC / 85°C BMS Rated
  • Neutrik D-Series Bulkhead
  • PCIe Gen3 x8 & VGA Loop
Opticis VGDF-200 VGA to Fiber DVI Converter | 500m SC Multimode WUXGA
View Opticis VGDF-200 VGA to Fiber DVI Converter | 500m SC Multimode WUXGA
opticisVGDF200

Opticis VGDF-200 VGA to Fiber DVI Converter | 500m SC Multimode WUXGA

Convert VGA to a single-fiber DVI link and transmit WUXGA (1920×1200) @ 60Hz up to 500 m (1,640 ft) over fiber with Self-EDID and VGA loop-through monitoring.

Standard ConfigurationDirect SKU

$1,399.00USD

Division 27 Specification Checklist

Specifying Optical & Isolated Links for Data Halls

Four architectural checkpoints when coordinating low-voltage pathways between white-space cages, gray-space electrical rooms, and NOC suites.

01 Plenum / LSZH

Pathway Fire & Jacket Code

Match raised-floor air-handling plenums and overhead trays with UL/CMP plenum or Low Smoke Zero Halogen (LSZH) jackets, and use detachable heads for tight conduit sweeps.

02 MPO-12 / LC / SC

Structured Trunk Termination

Select color-coded 12-core Type-A MPO, single-LC OM3/OM4 multimode (up to 300m), or duplex-LC OS2 single-mode (up to 1 km) modules to patch straight into existing panels.

03 Dual DC / RJ45

1RU Power & Telemetry

Replace individual wall-wart adapters in MDF/IDF cabinets with a 19-inch 1RU BR-600 frame featuring dual load-sharing DC feeds and LAN link diagnostics.

04 5 kV AC / 24V DC

Gray-Space Ground Isolation

Insert passive 5 kV galvanic RJ45 isolators on copper BMS/EPMS trunks crossing UPS or generator rooms, and power panel USB hubs from 24V DC DIN/screw terminals.

Data Center Infrastructure FAQ

Code Compliance, Rack Redundancy & Isolation

Answers for low-voltage contractors, MEP engineers, and facility operations teams planning white-space and NOC fit-outs.

Can these optical extenders run over pre-terminated MPO and LC patch panels?
Yes. Pure optical modules such as the Opticis DPC-MP14-TR terminate directly onto standard 12-core OM3 Type-A MPO trunks up to 330 meters, while detachable 1-LC and duplex-LC extenders (DPX, HDX, KVMX, FireNEX-80G, and FireNEX-U4F20G) patch across standard OM3/OM4 multimode or OS2 single-mode structured cabling.
Which cables meet raised-floor plenum or confined-space LSZH requirements?
Opticis DPOC-14N-P and USB-FC30AA ship with plenum-rated jackets, USC-CC32 is UL-certified, and detachable AOC families (DPFC-200D, DHFC-200D, LHM2-P, LHM2-N) plus LLMD-050 and SSMS-050 patch cords offer Plenum or Low Smoke Zero Halogen (LSZH) jacket constructions for air-handling pathways.
Why choose point-to-point fiber KVM over IP-KVM between server cages and the NOC?
Point-to-point optical KVM and USB extenders carry uncompressed signals over dedicated dielectric glass strands with zero network stack, MAC address, or routable IP surface—ideal for air-gapped colocation cages, security consoles, and zero-latency multi-monitor operator desks. Where multicast wall distribution is preferred, the PoE IPVDS-700-ED handles AV-over-IP layouts.
Where do passive Ethernet isolators fit in data center gray-space construction?
Copper Ethernet runs tying switchgear, UPS battery monitors, backup generators, or chiller skids back to IT/BMS switches often span separate grounding zones. Inline passive isolators (Baaske MI-1005 for 1GbE and MI-2005 for 2.5GBase-T Cat6) provide 5 kV AC galvanic isolation and surge protection without requiring power or IP configuration.
Return to top of page Return to top of page